Products

TICA Ceiling Type Air Handling Unit

TICA TFD-SC high-ceiling dedicated air handling unit with four jet nozzles

TICA High-Ceiling Dedicated Air Handling Unit

Product Overview

TICA High-Ceiling Dedicated Air Handling Unit

Designed specifically for large spaces such as industrial plants and logistics warehouses, the unit integrates a filter, fan motor, coil and jet nozzle.

A nylon filter is included as standard, with an optional oil-mist filter for environments affected by oily fumes. Bottom return air and side return air configurations are available to suit different installation layouts.

Integrated Components

Filter · Fan Motor · Coil · Jet Nozzle

Standard Filtration

Nylon Filter

Optional Filtration

Oil-Mist Filter

Return Air Options

Bottom Return Air · Side Return Air

Air Supply Design

Lower Air Velocity for Quieter Operation

Ultra-Slim Unit Design

Reduces unit width by approximately one-third and increases vehicle clearance by 45% compared with conventional cabinet-type jet units.

High-Airflow Multi-Nozzle Configuration

Provides wider air distribution and may reduce the number of required units by up to 50%.

Side Return Air Design

Supports wall-mounted installation for a cleaner and more integrated appearance.

Suspended TICA TFD-SC unit with multi-nozzle air supply design

Suspended Installation

No Ductwork Required for Faster Installation

Suspended indoor unit installation eliminates the need for air ducts, simplifies product selection and installation, and can reduce the construction period by up to 50%.

Lengthy Installation

Long installation cycles and complex connections with conventional hydronic systems.

Complex Floor Layouts

Complicated floor layouts that make floor-mounted units difficult to install.

Overhead Obstacles

Overhead crane rails and structural obstacles that complicate ductwork and water-pipe installation.

The unit can be quickly suspended from bridge structures, crane rails or ceiling supports. Its clean appearance integrates naturally into large industrial spaces while providing dependable indoor comfort.

TICA TFD-SC air handling unit suspended beneath an industrial building structure

Engineered Details

Built for Reliable Air-Handling Performance

Insulated panels, integrated drainage, certified heat exchange and a profile-free cabinet structure support reliable performance and practical maintenance in high-ceiling applications.

30 mm insulated panel detail

Proprietary High-Insulation Panel

  • 30 mm-thick panel.
  • Enhanced thermal insulation and sound attenuation.
Integrated drain pan detail

Sealant-Free Leak-Proof Design

  • One-piece foamed drain pan.
  • Drain-pan edges sit flush with the side panels.
  • The drain connection incorporates a built-in slope.
AHRI-certified heat exchanger

High-Efficiency Heat Exchanger

  • AHRI-certified heat exchanger.
  • RoHS-certified copper tubes.
  • 100% helium leak testing helps ensure leak-tight performance.
Frameless panel corner structure

First-of-Its-Kind Frameless, Profile-Free Direct-Joining Structure

  • Profile-free direct panel joining.
  • Assembly and disassembly require no specialized tools.
  • Multi-layer thermal-bridge prevention helps eliminate condensation risks.

Oil-Mist Filtration

Low-Resistance Washable Filter for Oily Environments

For processing workshops and other environments with oil mist, an optional low-resistance washable oil-mist filter provides a dedicated filtration solution.

The filter uses an air-permeable mesh with a multi-layer structure combining separation and collection layers. It efficiently captures oil-mist particles and dust, offers partial self-cleaning capability, and can be repeatedly washed and reused.

The side-access design allows fast removal and replacement for easier maintenance.

Low ResistanceWashable and ReusableSide-Access Maintenance
Washable oil-mist filter for TICA high-ceiling air handling unit

Technical Data

Technical Specifications

Model data for preliminary selection of the TFD-SC high-ceiling dedicated air handling unit.

TFD-SC technical specifications by model
ModelTFD042GCWSCTFD055GCWSCTFD074GCWSCTFD085GCWSC
Airflowm³/h4200550074008500
Rated Cooling CapacitykW42628084
Rated Heating CapacitykW46668490
Water FlowL/s1.83.03.84.2
Water ResistancekPa33625778
Power Supply380V 3N~50Hz
Motor Power - SpeedkW-P1.1-41.5-42.2-43.0-4
FilterNylon (Std)/Oil Mist (Opt)
Dimensionslong / mm2360286034603460
width / mm1080108011801180
height / mm700780870870
Weightkg200240320320
Chilled Water Pipe DiameterDN40DN40DN50DN50
Condensate Pipe DiameterDN25DN25DN25DN25
  1. Cooling: Inlet air dry bulb temperature 30°C, wet bulb temperature 24°C, water inlet/outlet temperature 7°C/12°C;
  2. Heating: Inlet air dry bulb temperature 18°C, hot water inlet/outlet temperature 60°C/50°C.
  3. Standard unit does not include control system; for integrated electromechanical control cabinet, please consult TICA.*

Project Support

Find the Right TICA High-Ceiling Dedicated Air Handling Unit Solution for Your Project

If you are evaluating TICA High-Ceiling Dedicated Air Handling Unit for a project, share your building type, required capacity, climate conditions and control requirements with our team.

To ensure your inquiry reaches us promptly, we recommend contacting us through WhatsApp using the contact panel on the right. You can also visit our official Alibaba.com store to discuss system selection and request a project quotation.

Visit Our Official Alibaba.com Store

Home Tel Mail WhatsApp