TIMS Extra Series

All-Scenario Healthy VRF System

TICA Inverter Multi System

Commercial VRF Reconsidered

Beyond Expectations, Flexible and Convenient

TIMS Extra is TICA’s healthy commercial VRF platform for shops, restaurants, offices, apartments, hotels and multi-use buildings. Compact outdoor units, long-piping flexibility, air purification, efficient inverter operation and intelligent control make it easier to adapt the system to different room layouts, installation conditions and management requirements.

Product Advantages

Nine Strengths in One Flexible Platform

From high-efficiency compressors and DC motors to precise refrigerant control, compact installation and healthier air, TIMS Extra brings nine coordinated advantages to commercial VRF projects.

High-Efficiency
Rotary Compressor

High-Efficiency
DC Brushless Motor

High-Performance
Plate Heat Exchanger

High-Precision
Electronic Expansion Valve

Energy-Saving
and Efficient

Flexible
and Compact

Convenient
Design

Healthy
and Safe

Environmentally
Friendly

Compact Outdoor Units

Multiple Cabinet Sizes for Flexible Installation

Designed for small, medium and larger applications, the TIMS Extra Series offers several outdoor-unit cabinet configurations. Its compact footprint reduces space requirements and helps simplify installation and maintenance.

Three TIMS Extra outdoor-unit cabinet sizes for different capacity ranges

Installation Flexibility

Multiple Cabinet Options for Different Installation Conditions

Compact footprints suit window ledges, narrow equipment platforms and layered outdoor-unit layouts where installation space or lifting access is limited.

Illustration of TIMS Extra outdoor units installed on commercial building platforms and window ledges
840 mm

10–16 kW Models

Compact single-fan cabinets fit building window ledges and other confined equipment spaces.

18–33.5 kW

Compact Dual-Fan Models

Dual-fan cabinets suit typical building installation conditions where outdoor-unit space is limited.

Engineering Flexibility

Extended Piping Capability for Greater Design Freedom

The long-piping design expands outdoor-unit placement options and supports complex building layouts while helping simplify system planning.

High-rise commercial building illustrating TIMS Extra long-piping lengths and height differences
200 mMaximum actual piping length
400 mMaximum total piping length
240 mMaximum equivalent piping length
30 mMaximum height difference between indoor units
110 mMaximum indoor/outdoor height difference
90 m*Maximum length after the first branch

Healthy Air

Four-Stage Purification for Cleaner Indoor Air

High-efficiency electrostatic filtration, silver-ion antibacterial treatment, chemical formaldehyde filtration and built-in UVC treatment work together to support healthier indoor environments.

99.9%PM2.5 purification efficiency
99.4%Microbial purification efficiency
90%Formaldehyde purification efficiency
TIMS Extra four-stage filtration and air-purification process
PM2.5 Filter Silver-Ion Antibacterial
Layer
Chemical Filter UVC Inactivation
Globally Patented Friction-Electrostatic Technology
Efficiently Captures Particles as Small as 0.3 μm
ArgenZil Silver-Ion Sterilization
Effectively Inhibits Bacterial Growth
Surface Primary-Amine (RNH₂) Impregnation
Targeted Formaldehyde Decomposition
265 nm Deep-UVC Sterilization
Powerful Inactivation

Purification figures are based on tests in a simulated 30 m³ occupied environment. Actual performance varies with room size, ventilation, pollutant sources, equipment configuration and filter maintenance.

Core Compressor Technology

Core Technology for Reliable Quality

TIMS Extra uses internationally recognized compressor technology and continuous core-system optimization to improve energy efficiency by up to 10%. This supports dependable performance, lower energy consumption and consistent product quality for commercial applications.

Cutaway view of TIMS Extra high-efficiency rotary compressor technology

Wide Range and Fast Response

Reliable Operation with Rapid Load Response

TIMS Extra maintains cooling operation from −5°C to 54°C and heating operation from −25°C to 27°C. The system can start in as little as 5 seconds and reach full output within 60 seconds, helping commercial spaces respond quickly to changing load demand.

Ultra-Wide Operating Range

Standard operating limits for the TIMS Extra series.

Cooling−5 to 54°C
Heating−25 to 27°C

Rapid Start and Full Output

Fast system response helps meet changing indoor load demand.

5 sSystem start
60 s100% capacity output
100% Capacity Demand
60 s
5 min reference
TICA TIMS ExtraConventional reference

Intelligent Building Management

Smarter Control for Efficient Building Operation

The third-generation remote centralized control platform supports local and remote monitoring, tenant-based energy billing and third-party BAS integration through BACnet, Lonworks and Modbus.

TIMS Extra control architecture with local controllers, remote terminals, tenant billing and building automation integration

System Planning

Simplified Refrigerant Piping Design and Selection

Outdoor and indoor units can be arranged through branch piping to suit multi-room commercial layouts. Final pipe sizing, branch selection and refrigerant charge should follow the installation manual and project-specific technical guidance.

TIMS Extra outdoor unit connected to multiple ducted indoor units through refrigerant branch piping

Maximum Number of Connected Indoor Units

Nominal Cooling Capacity (kW)1012.51415.5182022.425.228.533.5
Maximum Connected Indoor Units567891011131516

Refrigerant Piping Selection

Connected Indoor-Unit Capacity XLiquid PipeGas PipeBranch Joint
X < 16.8 kWφ9.52 mmφ15.88 mmTBP4022TA
16.8 kW ≤ X < 22.5 kWφ9.52 mmφ19.05 mmTBP4022TA
22.5 kW ≤ X < 33.0 kWφ9.52 mmφ22.20 mmTBP4033TA
33.0 kW ≤ Xφ12.70 mmφ25.40 mmTBP4072TA

Technical Specifications

TIMS Extra Outdoor-Unit Parameters

Compare capacity, efficiency, airflow, operating range and electrical data across the 220V and 380V outdoor-unit lineup to support preliminary model selection and project planning.

Cooling Capacity8.0–33.5 kW
Heating Capacity9.0–37.5 kW
APF4.90–5.23
RefrigerantR410A

220V Outdoor Units

ModelUnitTIMS080CSRECTIMS100CSRECTIMS112CSRECTIMS125CSRECTIMS140CSRECTIMS160CSRECTIMS180CSTEC
Power SupplyV/Hz220V~50Hz
Outdoor Unit Dimensions (L × W × H)mm865×310×700980×390×840980×390×1260
Outdoor Unit Weightkg58747884112
CapacityNominal CoolingkW81011.212.51415.518
Nominal HeatingkW911.512.513.5161720
Power ConsumptionNominal CoolingkW2.192.552.923.453.764.8
Nominal HeatingkW2.152.63.013.463.874.654.6
APF5.235.225.215.25.1
Outdoor Airflowm³/h33004800540060006600
NoiseCooling / HeatingdB(A)53/5654/5755/5856/5957/60
RefrigerantR410A
Refrigerant Chargekg2.152.653.33.84
Outdoor Operating RangeCooling°C−5 to 54
Heating°C−25 to 27
PipingLiquid / Gas Pipemmφ9.52/15.88φ9.52/19.05
Maximum Fuse CurrentMFAA2040
Minimum Circuit AmpacityMCAA16193236

380V Outdoor Units

ModelUnitTIMS180CSREATIMS200CSREATIMS224CSREATIMS252DSREATIMS285DSREATIMS335DSREA
Power SupplyV/Hz380V~50Hz
Outdoor Unit Dimensions (L × W × H)mm980×390×12601100×480×1550
Outdoor Unit Weightkg125165172
CapacityNominal CoolingkW182022.425.228.533.5
Nominal HeatingkW2022252731.537.5
Power ConsumptionNominal CoolingkW6.056.186.665.997.658.25
Nominal HeatingkW5.755.816.365.857.457.95
APF5.15.085.065.154.954.9
Outdoor Airflowm³/h8000900011300
NoiseCooling / HeatingdB(A)59/6358/6258/–59/–60/–
RefrigerantR410A
Refrigerant Chargekg5.678
Outdoor Operating RangeCooling°C−5 to 54−16 to 56
Heating°C−25 to 27−30 to 27
PipingLiquid / Gas Pipemmφ9.52/19.05φ12.7/22.2φ12.7/25.4
Maximum Fuse CurrentMFAA2032
Minimum Circuit AmpacityMCAA1725.225.826.5
Note:
  1. The conditions for rating nominal cooling capacity and nominal heating capacity are as follows: Cooling condition: indoor temperature: 27℃ DB / 19℃ WB, outdoor temperature: 35℃ DB / 24℃ WB, piping length: 7.5m, piping height difference: 0m; Heating condition: indoor temperature: 20℃ DB / 15℃ WB, outdoor temperature: 7℃ DB / 6℃ WB, piping length: 7.5m, piping height difference: 0m.
  2. The above noise values are measured in an anechoic chamber without reflected sound. Reflected sound effects must be taken into account on site. Under actual installation conditions, due to the influence of ambient noise and reflected noise, there will generally be slight differences from the values recorded in the sample.
  3. Select the fuse or air breaker according to the maximum fuse current, and select the electrical wiring specification according to the minimum circuit current.

Project Support

Find the Right TIMS Extra Series Solution for Your Project

If you are evaluating TIMS Extra Series for a project, share your building type, required capacity, climate conditions and control requirements with our team.